Number of found documents: 136
Published from to

Mimicking of thiram metabolism using electrochemistry hyphenated with mass spectrometry
Jaklová Dytrtová, Jana; Jakl, M.
2016 - Czech
On-line hyphenation of a home-made electrochemical cell with an electrospray ionization mass spectrometer (EC-ESI-MS) was investigated to be applicable in mimicking of thiram (T) metabolism. The EC-ESI-MS instrumental approach confirms the creation of the first metabolic product of T (Tm). Tm is created via the decay of the disulfide bond. The catalytic effect of copper originated from the copper working electrode to this reaction is discussed. On-line zapojení elektrochemické cely vlastní výroby před hmotnostní spektrometr s ionizací elektrosprejem (EC-ESI-MS) bylo studováno pro možné využití při simulaci metabolismu thiramu (T). Instrumentační přístup EC-ESI-MS potvrzuje vytvoření prvního metabolického produktu T (Tm). Tm se tvoří rozpadem disulfidové vazby. Je diskutován katalytický účinek mědi pocházející z měděné pracovní elektrody na tuto reakci. Keywords: cytochrome P450; oxidation; reduction; lab-on-chip; ex situ Available at various institutes of the ASCR
Mimicking of thiram metabolism using electrochemistry hyphenated with mass spectrometry

On-line hyphenation of a home-made electrochemical cell with an electrospray ionization mass spectrometer (EC-ESI-MS) was investigated to be applicable in mimicking of thiram (T) metabolism. The ...

Jaklová Dytrtová, Jana; Jakl, M.
Ústav organické chemie a biochemie, 2016

Quantification of Elements in Plant Materials by Electrothermal Vaporization Inductively Coupled Plasma Optical Emission Spectrometry
Šerá, Luisa; Matějková, Stanislava; Mestek, O.
2016 - Czech
This paper describes optimization and validation of operating conditions of electrothermal vaporization (ETV) inductively coupled plasma optical emission spectrometry (ICP-OES) method for quantification of Ba, Ca, Co, Cu, Fe, K, Mg, Mn, Na, P, Sr and Zn in plant materials. Besides the optimization of the temperature program, the selection of the gaseous modifier and the spectral wavelengths to be measured, it was studied how the sample quantity affects the result quality of the developed method. During the validation process, the accuracy and precision of the method were checked by analysis of a certified reference material. Limits of detection were estimated by analyses of blank samples. For almost all previously mentioned elements, the method meets requirements commonly applied on analyses by ETV combined with ICP-OES. Podařilo se vyvinout vhodnou analytickou metodu ICP-OES analýzy ve spojení s ETV pro rychlou kvantitativní analýzu rostlinných makro- i mikrobiogenních prvků. Pro tuto metodu byl zvolen plynný modifikátor, optimalizován teplotní program a zvoleny sledované spektrální čáry. U většiny těchto čar byla pomocí Mandelova testu linearity ověřena lineární kalibrační závislost intenzity signálu na množství analytu, u ostatních byla použita závislost kvadratická. Dále byly pro všechny spektrální čáry určeny LOD ze slepých pokusů. Také byl sledován vliv velikosti navážky vzorku na přesnost měření, kde optimální se jeví navážky mezi jedním a dvěma miligramy, v závislosti na očekávaném obsahu analytů ve vzorku. Analýzou CRM INCT-OBTL-5 Tabákových listů byla u 7 ze 12 stanovovaných analytů testem výtěžnosti potvrzena přesnost vyvinuté metody. I tak byla u většiny analytů zjištěna odchylka mezi certifikovanou a naměřenou hodnotou obsahu analytu v CRM do deseti procent, což je srovnatelné s publikovanými výsledky a s požadavky běžně kladenými na použitou metodu. Dalším cílem výzkumu bude posouzení vlivu průtoku nosného a „bypass“ plynu na průběh a přesnost analýzy. Dále se pokusíme vyzkoušet současné zapojení ETV a zmlžovače jako zdroje signálu interního standardu a posoudit vliv takového zapojení na průběh analýzy a její výsledky. Keywords: electrothermal vaporization; optical emission spectrometry; inductively coupled plasma; plants Available at various institutes of the ASCR
Quantification of Elements in Plant Materials by Electrothermal Vaporization Inductively Coupled Plasma Optical Emission Spectrometry

This paper describes optimization and validation of operating conditions of electrothermal vaporization (ETV) inductively coupled plasma optical emission spectrometry (ICP-OES) method for ...

Šerá, Luisa; Matějková, Stanislava; Mestek, O.
Ústav organické chemie a biochemie, 2016

ICP-OES with electrothermal vaporisation (ETV) as a possible tool for direct analysis of biologic samples
Matějková, Stanislava
2015 - Czech
Solid sampling electrothermal vaporization (ETV) inductively coupled plasma optical emission spectroscopy (ICP-OES) enable simple and rapid multielemental analysis of major, minor and trace elements without the need for pre-treatment of solid or liquid samples. By comparison with more common ICP-OES combined with a solution nebulization, the risk of contamination of analysed samples is reduced. The detection limits and the sample quantity needed for analysis via ETV-ICP-OES decrease as a result of the high-efectivity transport of the sample aerosol into the ICP torch. The connection of ETV unit to simultaneous ICP-OES allows us the fast direct and fully automatised analysis of numerous samples. The technique enable usually the combined calibration with home-made or certified solid and aqueous standards. We developed the methodology for tracking the carboran-based candidate-drugs time dependent concentration and for their pharmacokinetic evaluation. The method is based on direct boron or together boron and cobalt contents direct estimation in little amounts of fresh frozen mice tissues (5 – 10 mg of serum, brain or liver).\n Optická spektrometrie s indukčně vázaným plasmatem a elektrotermickou vaporizací (ETV-ICP-OES) je metodou umožňující jednoduché a rychlé přímé stanovení makro-, mikro- i stopových prvků v pevných i kapalných vzorcích bez předchozí úpravy. Metoda snižuje riziko kontaminace vzorků a vzhledem k vysoké efektivitě přenosu analytů do plasmatu je možno provádět analýzu z velmi malého množství vzorků (jednotky mg). V naší laboratoři byla vyvinuta metoda pro sledování hladiny a chování derivátů karboranů v organismu na základě stanovení koncentrace boru a kobaltu v malých množstvích myších tkání (5 – 10 mg séra, jater mebo mozku). Keywords: ETV-ICP-OES; biological samples; multielemental analysis Available at various institutes of the ASCR
ICP-OES with electrothermal vaporisation (ETV) as a possible tool for direct analysis of biologic samples

Solid sampling electrothermal vaporization (ETV) inductively coupled plasma optical emission spectroscopy (ICP-OES) enable simple and rapid multielemental analysis of major, minor and trace elements ...

Matějková, Stanislava
Ústav organické chemie a biochemie, 2015

Evaluation of proposed revitalization of the river Ploučnice close to Mimoň in terms of remobilization of historical contamination
Slabá, Eva; Matys Grygar, Tomáš; Elznicová, J.
2015 - Czech
The aim of the study was to estimate the uranium contamination in the alluvial sediments of original river beds of the Ploučnice river between 72-73 river kilometer on a left bank, near Mimoň town, and evaluate if the contamination should be included into preparation of revitalization projects. The study of contamination was started by mapping the gamma activity of the surface of the floodplain. Based on the resulting map the sediment samples were taken by hand earth drill from the former floodplain and channels abandoned in the 1980s by regulations. The samples were analysed by laboratory X-ray fluorescence (XRF). This step was followed by subsequent mapping by handheld XRF to specify the contamination pattern in the floodplain in more details. The evolution of watershed as well as the exact terrain model were processed by GIS program. Two major contaminated areas have been found, and further sampling was conducted. This enabled us to reconstruct the historical development of contamination at exceptional time scale resolution and describe precisely the evolution from the 19th century to the time of the regulation of that river reach. It has also been shown, that any revitalization in the near future would be probably thwarted due to extremely fast river changes which would cause an immediate re-introduction of the historical contamination into the fluvial system. Cílem této studie je zhodnotit historickou kontaminaci uranem v nivních sedimentech a původních korytech Ploučnice mezi 72. až 73. říčním kilometrem Ploučnice, v nivě na levém břehu řeky, cca 800m pod městem Mimoň a zdůvodnit, proč by mělo posouzení historické zátěže být zařazeno do procesu příprav revitalizačních prací. Bylo provedeno mapování gama aktivity na povrchu nivy, na jehož základě byly ručním žlábkovým vrtákem odebrány hloubkové profily nivních sedimentů i vzorky ze starých koryt odstavených regulacemi v 80. letech, které byly analyzovány rentgenovou fluorescenční spektrometrií (XRF). Následně byla provedena další mapování ručním XRF spektrometrem s cílem upřesnit rozložení uranu v jednom z nejvíc kontaminovaných míst v nivě. Vývoj vodního toku včetně studia přesného modelu terénu byl zpracován pomocí GIS. Analýza hloubkových profilů kontaminantů v nivě umožnila rekonstruovat vývoj historické kontaminace s výjimečným časovým rozlišením, představujícím zatím nejpodrobnější záznam vývoje znečištění od konce 19. století do regulace toku. Bylo prokázáno, že v minulosti docházelo k takovým rychlým bočním posunům meandrujícího toku, že by v důsledku případné revitalizace v blízké budoucnosti pravděpodobně došlo k remobilizaci historické kontaminace zpět do říčního systému. Keywords: Ploučnice river; uranium contamination; historical contamination; river floodplain; analysis of sediments; revitalization Available at various institutes of the ASCR
Evaluation of proposed revitalization of the river Ploučnice close to Mimoň in terms of remobilization of historical contamination

The aim of the study was to estimate the uranium contamination in the alluvial sediments of original river beds of the Ploučnice river between 72-73 river kilometer on a left bank, near Mimoň town, ...

Slabá, Eva; Matys Grygar, Tomáš; Elznicová, J.
Ústav organické chemie a biochemie, 2015

Detection of Dasatinib using Pre-reaction with Copper and Mass Spectrometry
Jaklová Dytrtová, Jana; Jakl, M.; Navrátil, Tomáš
2015 - Czech
The determination of dasatinib (DAS) was provided using front-end electrochemical separation with mass detection. The electrochemical separation is based on the reaction of DAS with copper solid electrode. The affinity of DAS to copper is supported by redox reaction yealding to DAS fragmentation. Stanovení dasatinibu (DAS) bylo provedeno pomocí elektrochemické separace následované hmotnostně spektrometrickou detekcí. Elektrochemická separace je založena na reakci DAS s pevnou měděnou elektrodou. Afinita DAS k mědi je podpořena redoxní reakcí vedoucí k fragmentaci DAS. Keywords: electrochemical separation; hyphenation; EC-ESI-MS; copper Available at various institutes of the ASCR
Detection of Dasatinib using Pre-reaction with Copper and Mass Spectrometry

The determination of dasatinib (DAS) was provided using front-end electrochemical separation with mass detection. The electrochemical separation is based on the reaction of DAS with copper solid ...

Jaklová Dytrtová, Jana; Jakl, M.; Navrátil, Tomáš
Ústav organické chemie a biochemie, 2015

Ionization techniques
Vrkoslav, Vladimír
2015 - Czech
Classification, principles and application examples of the most important ionization techniques were described. Byly popsány principy nejdůležitějších ionizačních technik, jejich rozdělení a příklady využití. Keywords: mass spectrometry; ion source; ionization Available at various institutes of the ASCR
Ionization techniques

Classification, principles and application examples of the most important ionization techniques were described.

Vrkoslav, Vladimír
Ústav organické chemie a biochemie, 2015

Ion mobility spectrometry DMS/FAIMS
Cvačka, Josef
2015 - Czech
Principles and application examples of ion mobility spectrometry DMS/FAIMS were described. Byly popsány principy mobilitní spektrometrie DMF/FAIMS a byly uvedeny příklady využití. Keywords: mass spectrometry; ion mobility; ion analyzers Available at various institutes of the ASCR
Ion mobility spectrometry DMS/FAIMS

Principles and application examples of ion mobility spectrometry DMS/FAIMS were described.

Cvačka, Josef
Ústav organické chemie a biochemie, 2015

Mobile mass spectrometry
Cvačka, Josef
2015 - Czech
Using and specifics of mobile mass spectrometers were explained. Byla vysvětlena specifika a příklady použití mobilních hmotnostních spektrometrů. Keywords: mass spectrometer; miniaturization; hand-held instruments Available at various institutes of the ASCR
Mobile mass spectrometry

Using and specifics of mobile mass spectrometers were explained.

Cvačka, Josef
Ústav organické chemie a biochemie, 2015

Ambient ionization techniques
Vrkoslav, Vladimír
2014 - Czech
Classification, principles and application examples of the most important ambient ionization techniques were described. Byly popsány principy nejdůležitějších ambientních ionizačních technik, jejich rozdělení a příklady využití. Keywords: mass spectrometry; analysis; desorption Available at various institutes of the ASCR
Ambient ionization techniques

Classification, principles and application examples of the most important ambient ionization techniques were described.

Vrkoslav, Vladimír
Ústav organické chemie a biochemie, 2014

(MA)LDI and MSI of small molecules
Vrkoslav, Vladimír
2014 - Czech
Using of MALDI/MS and LDI/MS for analysis of small molecular was explained. Byla vysvětlena specifika použití MALDI/MS a LDI/MS pro analýzu malých molekul. Keywords: mass spectrometry; mass spectrometry imaging; matrix assisted laser desorption/ ionization Available at various institutes of the ASCR
(MA)LDI and MSI of small molecules

Using of MALDI/MS and LDI/MS for analysis of small molecular was explained.

Vrkoslav, Vladimír
Ústav organické chemie a biochemie, 2014

About project

NRGL provides central access to information on grey literature produced in the Czech Republic in the fields of science, research and education. You can find more information about grey literature and NRGL at service web

Send your suggestions and comments to nusl@techlib.cz

Provider

http://www.techlib.cz

Facebook

Other bases