Supported Liquid Membranes for Hollow-Fibre Based Microextraction and Voltammetric Determination of Neuroblastoma Biomarkers
Josypčuk, Bohdan; Barek, J.; Josypčuk, Oksana
2018 - English
A new type of tubular detector (TD+AuxE) was proposed, fabricated, tested and compared\nwith a typical silver amalgam tubular detector developed earlier. Non-stop-flow differential\npulse voltammetric anodic stripping method (AS-DPV) and amperometric method in a\nglucose oxidase biosensor arrangement were tested. Both detectors were applied for AS-DPV\nmeasurements in flow systems for the first time. The proposed combination of tubular\ndetector with auxiliary electrode provides a much greater current response than the classic\narrangement with three individual electrodes. All relevant parameters (potentials of\naccumulation or detection, flow rate, analyte concentrations, shielding sleeve length, etc.)\nwere optimized for the developed TD+AuxE. Keywords: Flow analysis; Amperometry; Voltammetry Available at various institutes of the ASCR
Supported Liquid Membranes for Hollow-Fibre Based Microextraction and Voltammetric Determination of Neuroblastoma Biomarkers

A new type of tubular detector (TD+AuxE) was proposed, fabricated, tested and compared\nwith a typical silver amalgam tubular detector developed earlier. Non-stop-flow differential\npulse voltammetric ...

Josypčuk, Bohdan; Barek, J.; Josypčuk, Oksana
Ústav fyzikální chemie J. Heyrovského, 2018

Tourist interest in illicit zone of ice caves
Nováková, Eva; Kuda, František; Kubalíková, Lucie
2018 - English
Ledové sluje (Ice Caves) in the Podyjí National Park represents one of the most spectacular sites within the area. It consists of the large boulder field and several pseudokarst caverns on the north-western slope of the ridge that are very important from the ecological and geomorphological point of view. The access to the site is restricted for the visitors of National Park as there exists a risk of damage and disturbance of these unique phenomena; tourist can use the marked paths leading around the site, they can reach the top part of the ridge.\nCurrently, there are only several persons who have legal access to the site (employees of the National Park Administration and other researches with the permission issued by NP Administration). However, the installed sensor that counts the passages proved that the site is visited more frequently than it should be. The number of people who visit this site (situated within the first zone of National Park where there is no marked path and so the access is forbidden by decree) is quite alarming. Based on these findings, some proposals for the solution of this unfavourable situation are proposed and other possibilities how to avoid this undesirable phenomenon are discussed.\n Keywords: Podyji National Park; restricted area; passages monitoring Available in a digital repository NRGL
Tourist interest in illicit zone of ice caves

Ledové sluje (Ice Caves) in the Podyjí National Park represents one of the most spectacular sites within the area. It consists of the large boulder field and several pseudokarst caverns on the ...

Nováková, Eva; Kuda, František; Kubalíková, Lucie
Ústav geoniky, 2018

Proposal for loading tests of bridges - simulation and laboratory experiments
Bayer, Jan; Urushadze, Shota; Černý, Miloš
2018 - English
A new dynamic load testing of bridges is proposed and theoretically investigated. A transient analysis of passing vehicle over a bridge in ANSYS and an analytical program in MATLAB for the transient solution of piecewise linear mechanical structures were developed to assess the effects of the proposed dynamic load on a bridge model. According to the first laboratory experiments, it seems that the proposed travelling impulse load could surpass some of the shortcomings and limitations of the currently applied methods of bridge testing. The investigation is a part of a project aimed at drive-by identification of dynamic properties of bridges and further experimental and analytical research will follow. Keywords: dynamic loading tests; transient analysis; vibrations; vehicle-bridge interaction Available at various institutes of the ASCR
Proposal for loading tests of bridges - simulation and laboratory experiments

A new dynamic load testing of bridges is proposed and theoretically investigated. A transient analysis of passing vehicle over a bridge in ANSYS and an analytical program in MATLAB for the transient ...

Bayer, Jan; Urushadze, Shota; Černý, Miloš
Ústav teoretické a aplikované mechaniky, 2018

Lávka pro pěší Radotín - zatížení větrem dle EN 1991-1-4 a měření ve větrném tunelu
Göringer, J.; Hračov, Stanislav; Macháček, Michael
2018 - Czech
S ohledem na atypickou konstrukci lávky v Radotíně bylo nutno v rámci statického ověření řešit nestandardní účinky zatížení větrem, kdy EN 1991-1-4 poskytuje pro takto atypické konstrukce jen málo podpory. Zatížení větrem u takovéto konstrukce nevystupuje pouze jako náhradní statický účinek, ale zejména je nutné posoudit případné ztráty aerodynamické stability. Příspěvek předkládá postup stanovení problematiky podle EN 1991-1-4 včetně porovnání s výsledky z větrného tunelu. Due to the atypical design of the footbridge in Radotín the procedures for evaluation of the force coefficients presented in EN 1991-1-4 were experimentally verified in the wind tunnel. For the lack of the information about the structure behaviour on the edge of the aerodynamic instability the critical velocity for flutter was experimentally verified as well. The paper presents comparison of the approaches from EN 1991-1-4 with the results of the experiment. Keywords: wind load; footbridge; wind tunnel experiments Available at various institutes of the ASCR
Lávka pro pěší Radotín - zatížení větrem dle EN 1991-1-4 a měření ve větrném tunelu

S ohledem na atypickou konstrukci lávky v Radotíně bylo nutno v rámci statického ověření řešit nestandardní účinky zatížení větrem, kdy EN 1991-1-4 poskytuje pro takto atypické konstrukce jen málo ...

Göringer, J.; Hračov, Stanislav; Macháček, Michael
Ústav teoretické a aplikované mechaniky, 2018

Aplikace mikro-objemové voltametrické cely pro stanovení doxorubicinu hydrochloridu
Skalová, Štěpánka; Navrátil, Tomáš; Barek, J.; Vyskočil, V.
2018 - Czech
Byla úspěšně otestována aplikace mikro-objemové voltametrické cely na příkladu stanovení protinádorového léčiva doxorubicinu hydrochloridu. Objem analyzovaného vzorku činil 50 mikroL s LOD 0,39 micromol L-1 a LDR 0,4-10 mikromol L-1. Tato mikro-objemová cela byla také úspěšně použita k analýze tohoto analytu v modelových vzorcích pitné vody a lidské moči. Doxorubicin is an anticancer drug, which is used for treatment of various cancer types. It contains a quinone structure, similarly as some other drugs belonging to the same category (e.g., daunorubicin and epirubicin). Its monitoring can lead to optimization of individual patient dosages and increase chances for recovery of patients. A micro-volume voltammetric cell and differential pulse cathodic stripping voltammetry have been used for determination of doxorubicin hydrochloride. A volume of used sample was 50 microL. Limit of detection was 0.39 micromol L-1. An applicability of this method was verified on samples of drinking water and of human urine. Keywords: Doxorubicine hydrochloride; Voltametry; Micro-volume Available at various institutes of the ASCR
Aplikace mikro-objemové voltametrické cely pro stanovení doxorubicinu hydrochloridu

Byla úspěšně otestována aplikace mikro-objemové voltametrické cely na příkladu stanovení protinádorového léčiva doxorubicinu hydrochloridu. Objem analyzovaného vzorku činil 50 mikroL s LOD 0,39 ...

Skalová, Štěpánka; Navrátil, Tomáš; Barek, J.; Vyskočil, V.
Ústav fyzikální chemie J. Heyrovského, 2018

Chování metalothieneinů a fytochelatinů na rtuťových a amalgámových elektrodách
Šestáková, Ivana; Navrátil, Tomáš; Josypčuk, Bohdan
2018 - Czech
Při použití elektrod AgSAE či CuSAE pro elektrochemická měření s metalothioneiny či fytochelatiny vznikají příslušné Ag-MT, Cu-MT, Ag-PC či Cu-PC komplexy. V čistých elektrolytech a pro nízké koncentrace analytů jsou odezvy lineárně závislé na jejich koncentraci, odezvu je možné zvýšit akumulací při vhodném potenciálu. Pro reálné vzorky je podstatný negativní vliv matrice, který může vést až k nutnosti přípravy nového povrchu a jeho aktivace pro každý jednotlivý záznam. The presence of cysteine residues in molecules of metallothioneins or phytochelatins is crucial for their electrochemical behavior. At mercury electrodes, the reduction of\ntetracoordinated Cd and Zn in molecule of mamamalian MT is observed in solution of pH 8- 8.5, whereas with lowering pH or at presence of excessive ions, signals of differently coordinated or free metal ions appear. Such changes were confirmed on model complexes with phytochelatin PC2 .Using amalgam electrodes CuSAE or AgSAE for voltammetry of metallothioneins or phytochelatins, their Cu or Ag complexes are formed on the electrode surface, which could be with limitations - employed for the analytical purposes. Keywords: metallothioneins; amalgam electrode; voltammetry Available on request at various institutes of the ASCR
Chování metalothieneinů a fytochelatinů na rtuťových a amalgámových elektrodách

Při použití elektrod AgSAE či CuSAE pro elektrochemická měření s metalothioneiny či fytochelatiny vznikají příslušné Ag-MT, Cu-MT, Ag-PC či Cu-PC komplexy. V čistých elektrolytech a pro nízké ...

Šestáková, Ivana; Navrátil, Tomáš; Josypčuk, Bohdan
Ústav fyzikální chemie J. Heyrovského, 2018

Determination of Roughness Factor and Fractal Dimension of Zirconium in its Native and Surface Modified State using Atomic Force Microscopy. Effect of the Hydrogen\nEvolution Reaction on the Surface Structure
Novák, M.; Kocábová, Jana; Kolivoška, Viliam; Pospíšil, Lubomír; Macák, J.; Cichoň, Stanislav; Cháb, Vladimír; Hromadová, Magdaléna
2018 - English
Atomic force microscopy (AFM) was used to characterize surface morphology of pristine zirconium, Si modified and FeSi modified zirconium electrodes prior and after hydrogen evolution at potentials negative of the open circuit potential value. Two main characteristic parameters were obtained from the ex situ AFM height images, namely, the roughness factor and fractal dimension of the studied surface. The effect of hydrogen evolution reaction on the electrode surface morphology was discussed. Fractal dimension values were used successfully to explain the non ideality of the interfacial capacitance. Keywords: zirconium electrode; atomic force microscopy; fractal dimension Available at various institutes of the ASCR
Determination of Roughness Factor and Fractal Dimension of Zirconium in its Native and Surface Modified State using Atomic Force Microscopy. Effect of the Hydrogen\nEvolution Reaction on the Surface Structure

Atomic force microscopy (AFM) was used to characterize surface morphology of pristine zirconium, Si modified and FeSi modified zirconium electrodes prior and after hydrogen evolution at potentials ...

Novák, M.; Kocábová, Jana; Kolivoška, Viliam; Pospíšil, Lubomír; Macák, J.; Cichoň, Stanislav; Cháb, Vladimír; Hromadová, Magdaléna
Ústav fyzikální chemie J. Heyrovského, 2018

Vliv organických látek na charakter agregátů tvořených koagulací/flokulací při úpravě vody
Filipenská, Monika; Pivokonská, Lenka; Vašatová, Petra; Pivokonský, Martin
2018 - Czech
Cílem práce bylo popsat vliv různých znečišťujících příměsí (kaolinitové částice, COM peptidy/proteiny a jejich směs) na velikost, velikostní distribuci, tvar a strukturu agregátů tvořených v proměnných hydrodynamických podmínkách (různá gradient rychlosti) v konečné fázi vývoje agregace, tzv. steady state. Jako míchací zařízení byl zvolen Taylor-Couettův reaktor, který umožňuje neinvazivní pozorování agregátů. Vlastnosti agregátů byly vyhodnocovány metodou obrazové analýzy. Bylo zjištěno, že velikost a tvar agregátů je závislá na typu koagulačního činidla, typu koagulované přímesi a aplikovaném gradientu rychlosti. Železité koagulační činidlo produkuje větší a méně pravidelné agregáty než činidlo hlinité. Podle příměsi roste velikost (zároveň klesá kompaktnost a roste neuspořádanost) agregátů v pořadí kaolinit < COM < kaolinit + COM. Bylo zjištěno, že velikost agregátů se na aplikovaném gradientu rychlosti nemění plynule, jak bylo doposud předpokládání, ale při překročení hodnoty tzv. kritických gradientů rychlosti, dochází k její prudké změně. Změny ve velikosti agregátů se liší v závislosti na charakteru koagulovaných příměsí a byly vysvětleny pomocí rozdílných interakcí mezi znečišťující příměsí a koagulačním činidlem. Available at various institutes of the ASCR
Vliv organických látek na charakter agregátů tvořených koagulací/flokulací při úpravě vody

Cílem práce bylo popsat vliv různých znečišťujících příměsí (kaolinitové částice, COM peptidy/proteiny a jejich směs) na velikost, velikostní distribuci, tvar a strukturu agregátů tvořených v ...

Filipenská, Monika; Pivokonská, Lenka; Vašatová, Petra; Pivokonský, Martin
Ústav pro hydrodynamiku, 2018

Differences in Oxidation Mechanism of Selected Bioflavonoids, UV-Vis and IR Spectroelectrochemical Study
Sokolová, Romana; Fiedler, Jan; Ramešová, Šárka; Kocábová, Jana; Degano, I.; Quinto, A.; Křen, Vladimír
2018 - English
The oxidation of selected bioflavonoids (quercetin, rhamnazin, fisetin, rhamnetin, taxifolin, luteolin, silybin and 2,3-dehydrosilybin) was studied by electrochemical and spectroscopic methods. The oxidation mechanism and formation of oxidation products depends on the chemical structure. Only small differences in the chemical structure of compounds with flavone, flavanone and flavonol motif result in extremely variable oxidation pathways and products. Products of oxidation and further decomposition were determined by HPLC-ESIMS/MS and HPLC-DAD. Keywords: oxidation; flavonoids; decomposition Available at various institutes of the ASCR
Differences in Oxidation Mechanism of Selected Bioflavonoids, UV-Vis and IR Spectroelectrochemical Study

The oxidation of selected bioflavonoids (quercetin, rhamnazin, fisetin, rhamnetin, taxifolin, luteolin, silybin and 2,3-dehydrosilybin) was studied by electrochemical and spectroscopic methods. The ...

Sokolová, Romana; Fiedler, Jan; Ramešová, Šárka; Kocábová, Jana; Degano, I.; Quinto, A.; Křen, Vladimír
Ústav fyzikální chemie J. Heyrovského, 2018

Redox Properties of Fluorinated Derivatives of 1,3-Diphenylisobenzofuran Chromophores for Singlet Fission
Šimková, Ludmila; Ludvík, Jiří
2018 - English
Derivatives of 1,3-diphenylisobenzofuran attract interest because they should be efficient as the molecules for singlet fission. The understanding of singlet fission in isolated molecules might be advantageous for use as solar cell sensitizers. This study is focused on fluorinated derivatives of 1,3-diphenylisobenzofuran and the effect of the position of fluorine atoms on their redox properties. For characterization of the redox properties standard electrochemical methods, and in situ UV-vis and EPR spectroscopy techniques were used. Keywords: 1,3-diphenylisobenzofuran; fluorinated derivatives; spectroelectrochemistry Available on request at various institutes of the ASCR
Redox Properties of Fluorinated Derivatives of 1,3-Diphenylisobenzofuran Chromophores for Singlet Fission

Derivatives of 1,3-diphenylisobenzofuran attract interest because they should be efficient as the molecules for singlet fission. The understanding of singlet fission in isolated molecules might be ...

Šimková, Ludmila; Ludvík, Jiří
Ústav fyzikální chemie J. Heyrovského, 2018